UAPI SN850X Read-Only Re-inventory Evidence 2026-06-22
Read-only evidence from NUC, VPS/Cortex host, and Proxmox showing SN850X was not found on reachable hosts; SN8100 remains NUC boot/system disk.
Promotion Metadata
- Source feedback id:
138 - Source feedback ids:
138 - Promotion request id:
69 - Feedback category:
beneficial - Feedback source:
[REDACTED:high-entropy] - Feedback created at:
2026-06-22T19:40:53.990553+00:00 - Target slug:
[REDACTED:high-entropy] - Review state:
review - Reviewer note: AI lane auto-promoted redacted feedback into internal catalog context.
Source Feedback Body
Feedback 138
- Product:
uapi - Category:
beneficial - Related slug:
[REDACTED:high-entropy] - Source:
[REDACTED:high-entropy] - Created at:
2026-06-22T19:40:53.990553+00:00
SN850X Read-Only Re-inventory Evidence (2026-06-22)
Authority: Codex acting-operator read-only inventory. No writes, mounts, formats, installs, model work, route changes, or destructive actions were performed. Hardware serials were omitted from this evidence.
Scope
Checked reachable targets using approved SSH paths:
- NUC via VPS reverse tunnel:
nuc-via-reverse - VPS/Cortex host:
mail.united-ai.ca - Proxmox host:
pve250/Director
Result
SN850X was not found on any checked reachable host.
This does not prove the SN850X does not exist elsewhere. It proves only that the current read-only checks did not find SN850X on NUC-IPEX, the VPS/Cortex host, or the Proxmox host.
NUC-IPEX Evidence
- Host:
NUC-IPEX - Present internal disk:
WD_BLACK SN8100 2000GB - Bus: NVMe
- Health: Healthy / OK
- Boot/system: true
- C: volume free: about 705 GB
- USB
Asm 225device present with no media - SN850X filter result:
SN850X_NOT_PRESENT_ON_NUC
Conclusion: NUC storage remains SN8100 boot/system NVMe. SN850X is not attached to the NUC.
VPS/Cortex Evidence
- Host:
mail.united-ai.ca - Disk view: one
QEMU HARDDISK, 200G - Root filesystem: ext4 on
/dev/sda1, about 112G available /dev/disk/by-idmodel filter: no WD/NVMe/SN850X matchnvme list: no NVMe tool or no NVMe visible- LVM probe did not show relevant physical volumes
Conclusion: The VPS exposes virtual storage only in this check. No SN850X or WD NVMe device was visible from the VPS.
Proxmox Evidence
- Host:
Director - Proxmox:
pve-manager/9.1.4 - Disk view:
mmcblk0, about 58.2G eMMCnvme0n1, about 476.9G, modelTWSC TSC3AN512-F8T40S- Proxmox storage:
local, active, about 76G availablelocal-lvm, active, about 260G available- ZFS pools: none
- SN850X/WD/SN8100 model match: none relevant; only the TWSC NVMe appeared
Conclusion: Proxmox does not show SN850X. Its visible NVMe is a different 476.9G TWSC drive used for Proxmox/LVM storage.
Storage Modeling Decision
Do not model SN850X as UAPI-served capacity yet. Current evidence supports:
local.nuc.storage.sn8100.boot: present, boot/system disk, not spare capacityvps.cortex.storage.qemu200g: present virtual storage, not SN850Xlab.proxmox.storage.twsc476g: present Proxmox/LVM storage, not SN850Xstorage.fast.sn850x: unresolved/not found
Next Handoff
- Keep SN850X as unresolved until a physical or host-specific check finds it.
- Do not route workloads, model caches, weights, or UAPI storage claims to SN850X.
- If the operator knows another host/enclosure where the SN850X may live, run a new read-only inventory against that target.